Sign In | Join Free | My burrillandco.com
Home > AC Surge Protector >

SPD Modular AC Surge Protector 40KA Rail 35mm Installation

    Buy cheap SPD Modular AC Surge Protector 40KA Rail 35mm Installation from wholesalers
     
    Buy cheap SPD Modular AC Surge Protector 40KA Rail 35mm Installation from wholesalers
    • Buy cheap SPD Modular AC Surge Protector 40KA Rail 35mm Installation from wholesalers

    SPD Modular AC Surge Protector 40KA Rail 35mm Installation

    Ask Lasest Price
    Brand Name : FEEO
    Model Number : FSP-A40
    Certification : CE
    Price : USD 3.27-13.08 Unit
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 7000 PCS PER week
    Delivery Time : 7days
    • Product Details
    • Company Profile

    SPD Modular AC Surge Protector 40KA Rail 35mm Installation

    surge voltage protection, lightning protection over voltage protection


    Product Description
    lightning absorber Application:
    FSP-A series surge protection device (in short SPD,alias:surge suppressor surge arrester)is
    suitable for TN-S, TN-C-S, TT, IT etc, power supply system of AC 50/60Hz,<380V, installed on the
    joint of LPZ1 or LPZ2 and LPZ3. It's designed according to IEC61643-1, GB18802.1, it adopts
    35mm standard rail, there is a failure release mounted on the module of surge protection device,
    When the SPD fails in breakdown for over heat and over-current, the failure rlease will help electric
    equipments separate from the power supply system and give the indication signal, green means
    normal, red means abnormal, it also could be replaced for the module when has operating voltage.
    lightning absorber Product Features:
    1. Inside over-current and over-heat protection, temperature control open circuit.
    2. Module design, convenient installation, could be replaced online.
    3. Time of response <25ns
    4. The color of visible window shows operating status, green means normal, red means abnormal
    lightning absorber Technical Date:
    Technical ParametersFSP-A
    Rated Operating Voltage Un(V~)380V/220V
    Maximum Continuous Operating Voltage Uc(V~)275V320V385V385V385V420V
    Voltage protection Level Up(V~)kV≤1.0≤1.2≤1.8≤2.0≤2.2≤2.8
    Nominal Discharge Current ln (8/20s)kA51020304060
    Maximum Discharge Current lmax(8/20s)kA1020406080100
    Response Time (ns)<25
    Test StandardIEC61643.1, GB18802.1
    Operating Environment(centigrade)-40 ~+85℃
    Max Connection Line35mm2 hard wire/35mm2 strand wire copper line
    Recommended Connection Line16mm2 hard wire/25mm2 strand wire copper line
    InstallationStandard Rail 35mm
    Material of Outer CoveringBurning-proof Nylon

    SPD Modular AC Surge Protector 40KA Rail 35mm InstallationSPD Modular AC Surge Protector 40KA Rail 35mm Installation

    SPD Modular AC Surge Protector 40KA Rail 35mm Installation

    1. Air-termination system
    Metal objects and metal structures that are used to directly receive or bear lightning strikes, such as lightning rods, lightning belts (wires), lightning nets, etc.
    2. Down conductor system
    The metal conductor that connects the air-termination device to the grounding device.
    3. Earth termination system
    The sum of the grounding body and the connecting conductor of the grounding body.
    4. Earth electrode
    A metal conductor buried in the ground that directly contacts the ground. Also called ground electrode. Various metal components, metal facilities, metal pipes, metal equipment, etc. that are in direct contact with the earth can also be used as grounding bodies, which are called natural grounding bodies.
    5. Earth conductor
    From the grounding terminal of electrical equipment to the connecting wire or conductor of the grounding device, or from the metal object that needs equipotential bonding, the general grounding terminal, the grounding summary board, the general grounding bar, the equipotential bonding bar to the connecting wire or conductor of the grounding device.
    6. Direct lightning flash
    Lightning that directly strikes actual objects such as buildings, the ground or lightning protection devices.
    7. Ground potential counterattack Back flashover
    The lightning current passes through the grounding point or grounding system and causes the ground potential of the area to change. The ground potential counterattack will cause the potential of the grounding system to change, which may cause damage to electronic equipment and electrical equipment.
    8. Lightning protection system (LPS)
    Systems that reduce lightning damage to buildings and installations, including external and internal lightning protection systems.
    8.1 External lightning protection system External lightning protection system
    The lightning protection part of the exterior or body of a building (structure) usually consists of an air-termination device, a down conductor, and a grounding device to prevent direct lightning strikes.
    8.2 Internal lightning protection system
    The lightning protection part inside a building (structure) usually consists of an equipotential bonding system, a common grounding system, a shielding system, reasonable wiring, surge protectors, etc., which are mainly used to reduce and prevent lightning current from being caused in the protection space. The electromagnetic effect produced.


    Trade Ability

    Language Spoken
    English
    No. of Employees in Trade Department
    6-10 People
    Average Lead Time
    15
    Export License Registration NO
    04250042
    Total Annual Revenue
    confidential
    Total Export Revenue
    confidential
    Quality SPD Modular AC Surge Protector 40KA Rail 35mm Installation for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: YUEQING FEEO ELECTRIC CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)